Water-cooled unit commonly known as freezer, chiller, ice water machine, freezing water machine, cooling machine, etc., because of the wide use of all walks of life, so the name is countless.The principle of its properties is a multifunctional machine that removes liquid vapors through a compression or heat absorption refrigeration cycle.The steam compression chiller consists of four main components of the steam compression refrigeration cycle compressor, evaporator, condenser, and part of the metering device in the form of a different refrigerant.Absorption chiller uses water as a refrigerant, and relies on the water and lithium bromide solution between, in order to achieve a strong refrigeration effect of affinity.
Water-cooled unit are commonly used in air conditioning units and industrial cooling.In air conditioning systems, chilled water is usually distributed to heat exchangers or coils in air handling units or other types of terminal equipment for cooling in their respective Spaces, and then the cooling water is redistributed back to the cooling that has been cooled off.In industrial applications, chilled water or other liquids are cooled by pumps through processes or laboratory equipment.Industrial chiller is used to control product, mechanism and plant machinery cooling in all walks of life.
Technical Parameters
The technical data of water-cooled unit | |||||||||||||
Model | Power w | Evaporating temp. | Environment temp. | Condenser | Dimension① mm | lnstallation Size① mm | Connecting Pipe mm | Weight kg | |||||
Water m³/h | Model | A | B | C | D | E | Air | Liquid | |||||
BFS31 | 380~420V-3PH-50Hz | 0~-20℃ | 0~10℃ | 1.7 | SLKD003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 132 |
BFS41 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 25 | 12 | 159 | |||
BFS51 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 25 | 12 | 161 | |||
BFS81 | 3.9 | SLKD-008/B | 927 | 330 | 715 | 600 | 280 | 32 | 16 | 211 | |||
BFS101 | 4.9 | SLKD-010/B | 1127 | 330 | 716 | 800 | 280 | 32 | 19 | 225 | |||
BFS151 | 7.6 | SLKD-015/B | 1250 | 380 | 760 | 900 | 330 | 38 | 22 | 313 | |||
2YG-3.2 | 0~-20℃② | +12~-12℃ | 1.7 | SLKD-003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 125 | |
2YG-4.2 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 128 | |||
4YG-5.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 146 | |||
4YG-7.2 | 3.9 | SLKD-008/B1 | 927 | 330 | 715 | 600 | 280 | 28 | 16 | 154 | |||
4YG-10.2 | 7.6 | SLKD-015/B1 | 1250 | 380 | 760 | 900 | 330 | 28 | 16 | 218 | |||
4YG-15.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 264 | |||
4YG-20.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 271 | |||
4VG-25.2 | 12.2 | SLKD-030/B1 | 1650 | 380 | 810 | 1100 | 330 | 54 | 28 | 350 | |||
4VG-30.2 | 14.7 | SLKD-035/B1 | 1621 | 380 | 810 | 1100 | 330 | 54 | 28 | 370 | |||
6WG-40.2 | 20.7 | SLKD-050/B1 | 1850 | 430 | 860 | 1300 | 380 | 54 | 35 | 455 | |||
6WG-50.2 | 27 | SLKD-060/B1 | 1850 | 430 | 860 | 1300 | 380 | 54 | 35 | 474 | |||
4YD-3.2 | -5~-40℃③ | -10~-35℃ | 1.7 | SLKD-003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 138 | |
4YD-4.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 28 | 12 | 143 | |||
4YD-5.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 28 | 12 | 146 | |||
4YD-8.2 | 4.9 | SLKD-010/B1 | 1127 | 330 | 715 | 800 | 280 | 35 | 16 | 205 | |||
4YD-10.2 | 4.9 | SLKD-010/B1 | 1127 | 330 | 715 | 800 | 280 | 35 | 16 | 219 | |||
4VD-15.2 | 7.6 | SLKD-015/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 304 | |||
4VD-20.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 54 | 22 | 317 | |||
6WD-30.2 | 12.2 | SLKD-030/B1 | 1650 | 380 | 810 | 1100 | 330 | 54 | 22 | 378 | |||
6WD-40.2 | 18.3 | SLKD-040/B1 | 1621 | 380 | 810 | 1100 | 330 | 54 | 28 | 402 |
①The above-mentioned parameters are subject to actual data.
②Addieional cooiing or limited suction gas temperature if eveaporating temperature is under -15℃.
③Addieional cooiing or limited suction gas temperature or liquid injection cooling if eveaporating temperature is under -20℃.
Product detail pictures:
Related Product Guide:
Persisting in "High quality, Prompt Delivery, Aggressive Price", now we have established long-term cooperation with consumers from equally overseas and domestically and get new and old clients' large comments for Quality Inspection for Walk In Refrigeration System - Water Chiller – Xinneng , The product will supply to all over the world, such as: Jakarta, Japan, Nepal, They're durable modeling and promoting well all over the world. Under no circumstances disappearing key functions in a brief time, it's a should for you personally of fantastic quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the business make an awesome efforts to expand its international trade, raise its enterprise. rofit and improve its export scale. We are confident that we'll have a vibrant prospect and to be distributed all over the world in the years to come.