Professional China Refrigeration Unit For Cold Room - Water Chiller – Xinneng
Professional China Refrigeration Unit For Cold Room - Water Chiller – Xinneng Detail:
Product Introduction
Water-cooled unit commonly known as freezer, chiller, ice water machine, freezing water machine, cooling machine, etc., because of the wide use of all walks of life, so the name is countless.The principle of its properties is a multifunctional machine that removes liquid vapors through a compression or heat absorption refrigeration cycle.The steam compression chiller consists of four main components of the steam compression refrigeration cycle compressor, evaporator, condenser, and part of the metering device in the form of a different refrigerant.Absorption chiller uses water as a refrigerant, and relies on the water and lithium bromide solution between, in order to achieve a strong refrigeration effect of affinity.
Water-cooled unit are commonly used in air conditioning units and industrial cooling.In air conditioning systems, chilled water is usually distributed to heat exchangers or coils in air handling units or other types of terminal equipment for cooling in their respective Spaces, and then the cooling water is redistributed back to the cooling that has been cooled off.In industrial applications, chilled water or other liquids are cooled by pumps through processes or laboratory equipment.Industrial chiller is used to control product, mechanism and plant machinery cooling in all walks of life.
Technical Parameters
The technical data of water-cooled unit | |||||||||||||
Model | Power w | Evaporating temp. | Environment temp. | Condenser | Dimension① mm | lnstallation Size① mm | Connecting Pipe mm | Weight kg | |||||
Water m³/h | Model | A | B | C | D | E | Air | Liquid | |||||
BFS31 | 380~420V-3PH-50Hz | 0~-20℃ | 0~10℃ | 1.7 | SLKD003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 132 |
BFS41 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 25 | 12 | 159 | |||
BFS51 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 25 | 12 | 161 | |||
BFS81 | 3.9 | SLKD-008/B | 927 | 330 | 715 | 600 | 280 | 32 | 16 | 211 | |||
BFS101 | 4.9 | SLKD-010/B | 1127 | 330 | 716 | 800 | 280 | 32 | 19 | 225 | |||
BFS151 | 7.6 | SLKD-015/B | 1250 | 380 | 760 | 900 | 330 | 38 | 22 | 313 | |||
2YG-3.2 | 0~-20℃② | +12~-12℃ | 1.7 | SLKD-003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 125 | |
2YG-4.2 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 128 | |||
4YG-5.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 146 | |||
4YG-7.2 | 3.9 | SLKD-008/B1 | 927 | 330 | 715 | 600 | 280 | 28 | 16 | 154 | |||
4YG-10.2 | 7.6 | SLKD-015/B1 | 1250 | 380 | 760 | 900 | 330 | 28 | 16 | 218 | |||
4YG-15.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 264 | |||
4YG-20.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 271 | |||
4VG-25.2 | 12.2 | SLKD-030/B1 | 1650 | 380 | 810 | 1100 | 330 | 54 | 28 | 350 | |||
4VG-30.2 | 14.7 | SLKD-035/B1 | 1621 | 380 | 810 | 1100 | 330 | 54 | 28 | 370 | |||
6WG-40.2 | 20.7 | SLKD-050/B1 | 1850 | 430 | 860 | 1300 | 380 | 54 | 35 | 455 | |||
6WG-50.2 | 27 | SLKD-060/B1 | 1850 | 430 | 860 | 1300 | 380 | 54 | 35 | 474 | |||
4YD-3.2 | -5~-40℃③ | -10~-35℃ | 1.7 | SLKD-003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 138 | |
4YD-4.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 28 | 12 | 143 | |||
4YD-5.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 28 | 12 | 146 | |||
4YD-8.2 | 4.9 | SLKD-010/B1 | 1127 | 330 | 715 | 800 | 280 | 35 | 16 | 205 | |||
4YD-10.2 | 4.9 | SLKD-010/B1 | 1127 | 330 | 715 | 800 | 280 | 35 | 16 | 219 | |||
4VD-15.2 | 7.6 | SLKD-015/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 304 | |||
4VD-20.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 54 | 22 | 317 | |||
6WD-30.2 | 12.2 | SLKD-030/B1 | 1650 | 380 | 810 | 1100 | 330 | 54 | 22 | 378 | |||
6WD-40.2 | 18.3 | SLKD-040/B1 | 1621 | 380 | 810 | 1100 | 330 | 54 | 28 | 402 |
①The above-mentioned parameters are subject to actual data.
②Addieional cooiing or limited suction gas temperature if eveaporating temperature is under -15℃.
③Addieional cooiing or limited suction gas temperature or liquid injection cooling if eveaporating temperature is under -20℃.
Product detail pictures:
Related Product Guide:
It can be our accountability to satisfy your preferences and competently provide you. Your satisfaction is our greatest reward. We are searching ahead towards your visit for joint growth for Professional China Refrigeration Unit For Cold Room - Water Chiller – Xinneng , The product will supply to all over the world, such as: Ukraine, Tunisia, European, The best and original quality for spare parts is a most important factor for transportation. We may stick on supplying original and good quality parts even a little profit earned. God will bless us to do kindness business forever.