Water-cooled unit commonly known as freezer, chiller, ice water machine, freezing water machine, cooling machine, etc., because of the wide use of all walks of life, so the name is countless.The principle of its properties is a multifunctional machine that removes liquid vapors through a compression or heat absorption refrigeration cycle.The steam compression chiller consists of four main components of the steam compression refrigeration cycle compressor, evaporator, condenser, and part of the metering device in the form of a different refrigerant.Absorption chiller uses water as a refrigerant, and relies on the water and lithium bromide solution between, in order to achieve a strong refrigeration effect of affinity.
Water-cooled unit are commonly used in air conditioning units and industrial cooling.In air conditioning systems, chilled water is usually distributed to heat exchangers or coils in air handling units or other types of terminal equipment for cooling in their respective Spaces, and then the cooling water is redistributed back to the cooling that has been cooled off.In industrial applications, chilled water or other liquids are cooled by pumps through processes or laboratory equipment.Industrial chiller is used to control product, mechanism and plant machinery cooling in all walks of life.
Technical Parameters
The technical data of water-cooled unit | |||||||||||||
Model | Power w | Evaporating temp. | Environment temp. | Condenser | Dimension① mm | lnstallation Size① mm | Connecting Pipe mm | Weight kg | |||||
Water m³/h | Model | A | B | C | D | E | Air | Liquid | |||||
BFS31 | 380~420V-3PH-50Hz | 0~-20℃ | 0~10℃ | 1.7 | SLKD003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 132 |
BFS41 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 25 | 12 | 159 | |||
BFS51 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 25 | 12 | 161 | |||
BFS81 | 3.9 | SLKD-008/B | 927 | 330 | 715 | 600 | 280 | 32 | 16 | 211 | |||
BFS101 | 4.9 | SLKD-010/B | 1127 | 330 | 716 | 800 | 280 | 32 | 19 | 225 | |||
BFS151 | 7.6 | SLKD-015/B | 1250 | 380 | 760 | 900 | 330 | 38 | 22 | 313 | |||
2YG-3.2 | 0~-20℃② | +12~-12℃ | 1.7 | SLKD-003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 125 | |
2YG-4.2 | 2.6 | SLKD-005/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 128 | |||
4YG-5.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 146 | |||
4YG-7.2 | 3.9 | SLKD-008/B1 | 927 | 330 | 715 | 600 | 280 | 28 | 16 | 154 | |||
4YG-10.2 | 7.6 | SLKD-015/B1 | 1250 | 380 | 760 | 900 | 330 | 28 | 16 | 218 | |||
4YG-15.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 264 | |||
4YG-20.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 271 | |||
4VG-25.2 | 12.2 | SLKD-030/B1 | 1650 | 380 | 810 | 1100 | 330 | 54 | 28 | 350 | |||
4VG-30.2 | 14.7 | SLKD-035/B1 | 1621 | 380 | 810 | 1100 | 330 | 54 | 28 | 370 | |||
6WG-40.2 | 20.7 | SLKD-050/B1 | 1850 | 430 | 860 | 1300 | 380 | 54 | 35 | 455 | |||
6WG-50.2 | 27 | SLKD-060/B1 | 1850 | 430 | 860 | 1300 | 380 | 54 | 35 | 474 | |||
4YD-3.2 | -5~-40℃③ | -10~-35℃ | 1.7 | SLKD-003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 138 | |
4YD-4.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 28 | 12 | 143 | |||
4YD-5.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 28 | 12 | 146 | |||
4YD-8.2 | 4.9 | SLKD-010/B1 | 1127 | 330 | 715 | 800 | 280 | 35 | 16 | 205 | |||
4YD-10.2 | 4.9 | SLKD-010/B1 | 1127 | 330 | 715 | 800 | 280 | 35 | 16 | 219 | |||
4VD-15.2 | 7.6 | SLKD-015/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 304 | |||
4VD-20.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 54 | 22 | 317 | |||
6WD-30.2 | 12.2 | SLKD-030/B1 | 1650 | 380 | 810 | 1100 | 330 | 54 | 22 | 378 | |||
6WD-40.2 | 18.3 | SLKD-040/B1 | 1621 | 380 | 810 | 1100 | 330 | 54 | 28 | 402 |
①The above-mentioned parameters are subject to actual data.
②Addieional cooiing or limited suction gas temperature if eveaporating temperature is under -15℃.
③Addieional cooiing or limited suction gas temperature or liquid injection cooling if eveaporating temperature is under -20℃.
Product detail pictures:
Related Product Guide:
We attempt for excellence, provider the customers", hopes to be the most beneficial cooperation team and dominator enterprise for staff, suppliers and shoppers, realizes value share and continuous advertising for Fixed Competitive Price Precision Cooling Unit - Water Chiller – Xinneng , The product will supply to all over the world, such as: Lyon, Estonia, Honduras, When It produced, it making use of the world's major method for reliable operation, a low failure price, it appropriate for Jeddah shoppers choice. Our enterprise. s situated inside the national civilized cities, the website traffic is very hassle-free, unique geographical and financial circumstances. We pursue a "people-oriented, meticulous manufacturing, brainstorm, make brilliant" company philosophy. Strict good quality management, fantastic service, affordable cost in Jeddah is our stand around the premise of competitors. If needed, welcome to make contact with us by our web page or phone consultation, we'll be delighted to serve you.